About FCIP
S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m

VRRP

Figure 41-6
configuration example. This configuration requires at least two physical Gigabit Ethernet ports
connected to the Ethernet switch on the island where you need to implement high availability using
VRRP.
Figure 41-6
The following characteristics set VRRP solutions apart from other solutions:

Ethernet PortChannels

Figure 41-7
addresses the problem caused by individual Gigabit Ethernet link failures.
Figure 41-7
The following characteristics set Ethernet PortChannel solutions apart from other solutions:
Cisco MDS 9000 Family CLI Configuration Guide
41-6
displays a Virtual Router Redundancy Protocol (VRRP)-based high availability FCIP
VRRP-Based High Availability
FC fabric
IP interfaces are in VRRP group
If the active VRRP port fails, the standby VRRP port takes over the VRRP IP address.
When the VRRP switchover happens, the FCIP link automatically disconnects and reconnects.
This configuration has only one FCIP (E)ISL link.
displays an Ethernet PortChannel-based high- availability FCIP example. This solution
Ethernet PortChannel-Based High Availability
FC fabric
Ethernet ports are
in PortChannel
The Gigabit Ethernet link level redundancy ensures a transparent failover if one of the Gigabit
Ethernet links fails.
Two Gigabit Ethernet ports in one Ethernet PortChannel appear like one logical Gigabit Ethernet