1 Alarms
1.6
Identifier
Effect
Identifier
Effect
Identifier
Effect
Identifier
Effect
Identifier
Effect
Identifier
Effect
Identifier
Effect
Identifier
Effect
1-600
Cancel criteria for alarms
CANCELCLEAR
The alarm is cleared by pressing the Cancel key in any channel. It is also cleared by the
Start part program key.
- Clear the alarm with the Clear key or with NC START.
CLEARHIMSELF
Self-clearing alarm. The alarm is cleared not by an operator action but explicitly by a
"clearAlarm" in programmed the NCK source code.
- Alarm display showing cause of alarm disappears. No further operator action necessary.
NCSTARTCLEAR
The alarm is cleared by starting a program in the channel in which the alarm occurred.
The alarm is also cleared by an NC reset.
- Clear the alarm with NC START or the RESET key and continue the program.
POWERONCLEAR
The alarm is cleared by switching the control off/on.
- Switch control OFF - ON.
RESETCLEAR
The alarm is cleared by pressing the Reset key in the channel in which the alarm
occurred.
- Clear alarm with the RESET key. Restart part program.
BAGRESETCLEAR
The alarm is cleared by a "BAGRESETCLEAR" command or by carrying out a reset in all
channels of this mode group.
- Press the RESET key to clear alarm in all channels of this mode group. Restart part
program.
NCKRESETCLEAR
The alarm is cleared by an "NCKRESETCLEAR" command or by carrying out a reset in
all channels.
- Clear alarm in all channels with the RESET key. Restart part program.
NOCLEAR
The clear information is only required for the internal pseudo alarm number
EXBSAL_NOMOREALARMS.
SINUMERIK 840D/840Di/810D Diagnostics Guide (DA) – 11.02 Edition
Siemens AG, 2002. All rights reserved
11.02