Chapter 7
Cisco RFGW-10 UEQAM System Specifications
Table 7-2
Cisco RFGW-10 UEQAM Power Requirements
Component/Attribute
Redundant power supply
Power input
Power consumption
Heat Dissipation
Airflow
Operating temperature (nominal)
Operating temperature (short-term)
Operating humidity (nominal) (relative humidity)
Operating humidity (short-term)
Storage temperature
Storage (relative humidity)
Operating altitude
Altitude, nonoperational: over allowable temperature range
Network Equipment Building Standards (NEBS)
EMC standards
CE marking
OL-16264-04
Requirements
Dual power supply by default; DC only
Worldwide ranging DC (–40VDC to –60VDC: –48VDC
Nominal)
Maximum (DC): 4536W
4536W (15,474.06 Btu/hour)
Front to back flow with 800 CFM exhaust volume (main fan
tray + DC PEM fans) at full flow
32 to 104ºF (0 to 40ºC)
23 to 122°F (–5 to 50°C)
10 to 85%
5 to 90%
–40 to 158°F (–40 to 70°C)
5 to 95%
–200 to 10000 feet (–60 to 3050 m)
–200 to 30,000 feet (–60 to 9144 m)
GR-1089 and GR-63
Cisco RF Gateway 10 Hardware Installation Guide
Power Requirements
7-3