hit counter script

Cisco 7604 Configuration Manual page 944

Ios software configuration guide
Hide thumbs Also See for 7604:
Table of Contents

Advertisement

Global Health-Monitoring Tests
For additional information (including configuration examples and troubleshooting information), see the
Tip
documents listed on this page:
http://www.cisco.com/en/US/products/hw/routers/ps368/tsd_products_support_series_home.html
Global Health-Monitoring Tests
The global health monitoring tests consist of the following tests:
TestSPRPInbandPing, page A-2
TestMacNotification, page A-3
TestSPRPInbandPing
The TestSPRPIinbandPing test detects most runtime software driver and hardware problems on
supervisor engines by running diagnostic packet tests using the Layer 2 forwarding engine, the Layer 3
and 4 forwarding engine, and the replication engine on the path from the switch processor to the route
processor. Packets are sent at 15-second intervals. Ten consecutive failures of the test results in failover
to the redundant supervisor engine (default) or reload of the supervisor engine if a redundant supervisor
engine is not installed.
Table A-1
Attribute
Disruptive/Nondisruptive
Recommendation
Default
Release
Corrective action
Hardware support
TestScratchRegister
The TestScratchRegister test monitors the health of application-specific integrated circuits (ASICs) by
writing values into registers and reading back the values from these registers. The test runs every 30
seconds. Five consecutive failures causes a supervisor engine to switchover (or reset), if you are testing
the supervisor engine, or in the module powering down when testing a module.
Cisco 7600 Series Router Cisco IOS Software Configuration Guide, Release 12.2SX
A-2
IPSEC Services Modules Tests, page A-32
Stress Tests, page A-33
Critical Recovery Tests, page A-34
General Tests, page A-36
TestSPRPInbandPing Test Attributes
Description
Nondisruptive.
Do not disable. Test is automatically disabled during
CPU-usage spikes in order to maintain accuracy.
On.
12.1(13)E, 12.2(14)SX to12.2(17d)SXB5, and 12.2(18)SXD.
Reset the active supervisor engine.
Active and standby supervisor engine.
Appendix A