To select and set multiple button numbers, place a
check mark beside the target button numbers to set.
To select and set all button numbers, place a check
mark in the Select All checkbox.
4
Press the [Edit] button.
The [Select V/K Pair] window appears.
5
Set the button for the V/K pair signals to assign to the
on state.
Select a tab to change the V/K pair number to display.
6
Press [OK].
To inhibit operation
Select the target button number and set the [Inhibit] switch
to the on state.
To delete a button number setting
Select the target button number to delete and press the
[Delete] button.
The settings for all the button numbers not deleted move
up in sequence.
To insert a button number setting
Select the button number at the insertion position and press
[Insert].
A button number is inserted and the settings of all other
buttons are shifted by one.
To return to the initial settings
Press the [Default Recall] button, check the message, then
press [OK].
Setting the Shift Button
Setting the [SHIFT] button operation mode
You can set the operation mode of the [SHIFT] button
assigned to the right edge of the cross-point button row in
the cross-point control block.
You can set it for each cross-point assign table.
Note
The [SHIFT] button operation mode is set by the settings
of the cross-point assign table of the switcher bank,
regardless of the buses assigned to the cross-point button
rows.
1
Open the Home > Setup > Xpt Assign > Shift Mode
menu (19102.41).
2
Select the target table to set.
To select and set multiple tables, place a check mark
beside the target tables to set.
To select and set all tables, place a check mark in the
Select All checkbox.
3
Press the [Xpt Shift Mode] button and select an
operation mode from the pull-down list.
Hold: Functions as a shift button, and the shifted state
of a cross-point button is enabled while the button
is pressed.
Lock: Functions as a shift button, and pressing a
button toggles between the shifted and unshifted
states of the cross-point.
Off: Functions as a cross-point button, namely, button
number 24 on a 24-button system or button
number 16 on a 16-button system.
Setting the [SHIFT ALL] button operation
mode
You can set the operation mode of the [SHIFT ALL]
button assigned to the function button section of the cross-
point control block.
The setting is common to all cross-point assign tables.
1
Open the Home > Setup > Xpt Assign > Shift Mode
menu (19102.41).
2
Set the operation mode using the [Shift All Hold]
button.
On: Set to Hold mode. The shifted state of the cross-
point buttons for all buses is enabled while the
[SHIFT ALL] button is pressed.
Off: Set to Lock mode. Each time the [SHIFT ALL]
button is pressed, the cross-points are switched
between the shifted and unshifted states for all
buses.
302