9-20
Command Diagnostic Messages

C0105 Maximum length for MDT exceeded

Cause
In S-0-0015, Telegram type parameter telegram
type 7 (configured telegram) was set
Length of configured data record in MDT that is
determined by S-0-0024, Config. list of the master
data telegram exceeds the maximum allowed value
entered in S-0-0186, Length of the configurable
data record in the MDT

C0106 Config. IDNs for AT not configurable

Cause
in the S-0-0015, Telegram type parameter the
telegram type 7 (configured telegram) was set
in S-0-0016, Custom amplifier telegram
configuration list there were some parameters
entered that are not contained in S-0-0187, List of
configurable data in the AT
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
During the execution of the command S-0-0127, C0100 Communication
phase 3 transition check an error with regard to the telegram
configuration of the master communication was detected.
Remedy
Set priority telegram (telegram type = 0..6) in S-0-0015,
Telegram type parameter
Reduce number of configured parameters in MDT
(S-0-0024, Config. list of the master data telegram)
Note:
List parameters are only allowed in the multiplex channel.
For removing command errors see "Command Errors"
C0105 - Attributes
Display:
C0105
Mess. no.:
C0105 (hex)
Supported by Firmware Variant:
During
the
transition
communication phase 3 (C0100) an error with regard to the telegram
configuration of the master communication was detected.
Remedy
set priority telegram (telegram type = 0..6) in S-0-0015,
Telegram type parameter
in S-0-0016, Custom amplifier telegram configuration
list those parameters have to be entered that are
contained in S-0-0187, List of configurable data in the
AT
Note:
List parameters are only allowed in the multiplex channel.
C0106 - Attributes
Display:
C0106
Mess. no.:
C0106 (hex)
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
check
from
communication
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
Rexroth IndraDrive
phase 2
to

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents

Save PDF