C0212 Invalid control section data (->S-0-0022)
For HMS, HMD, HCS
For HMV
Cause
Reading error from I2C-Prom due to hardware defect
DOK-INDRV*-GEN-**VRS**-WA01-EN-P
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Supported by Firmware Variant:
Supported by Supply Unit:
During the execution of the command S-0-0128, C0200 Communication
phase 4 transition check an error during the initialization of amplifier
data was detected. The respective parameters are entered in the list
S-0-0022, IDN list of invalid operating data for communication
phase 3.
During the initialization of the device data error was detected.
Remedy
If possible, replace hardware; otherwise contact our
service department
For removing command errors see "Command Errors"
C0212 - Attributes
Display:
C0212
Mess. no.:
C0212 (hex)
Command Diagnostic Messages
FWA-INDRV*-MPH02VRS-MS
FWA-INDRV*-MPB02VRS-MS
FWA-INDRV*-MPD02VRS-MS
HMV01
9-51