10-4
Handling, Diagnostic and Service Functions
XX:F9002
XX:F2100
XX:F CKS
Cause
Checksums of programmed modules are calculated
after firmware update. Calculated and entered
checksums were detected to be different
XX:F ACC
Cause
Several possibilities of firmware update (serial and
MMC) were used simultaneously. An access
conflict has occurred
XX:F2101
LSA Control S.L. www.lsa-control.com comercial@lsa-control.com (+34) 960 62 43 01
Brief Description: Error: operating system error
See F9002 Error internal RTOS function call
Brief Description: Error: internal memory defective
See F2100 Incorrect access to command value memory
Brief Description: Error: checksum error
Remedy
Carry out firmware update again; should error occur
again, please contact our service department
Note:
"FL:F CKS" means firmware loader and "LD:F CKS" means
loader in control section.
Brief Description: Error: access error
Remedy
Restart firmware update using only one possibility (serial
or MMC)
Note:
"FL:F ACC" means firmware loader and "LD:F ACC" means
loader in control section.
Brief Description: Error: MMC defective
See F2101 It was impossible to address MMC