hit counter script

Cisco Catalyst 3560-X Command Reference Manual page 772

Hide thumbs Also See for Catalyst 3560-X:
Table of Contents

Advertisement

show power inline
Catalyst 3750-X and 3560-X Switch Command Reference
2-740
Downloaded from
www.Manualslib.com
Gi3/0/9
NO
Gi3/0/10
NO
<output truncated>
This is an example of output from the show power inline police command on a Catalyst 3750-X switch.
Table 2-47
describes the output fields.
Switch> show power inline police
Module
Available
Used
(Watts)
(Watts)
------
---------
--------
1
370.0
3
865.0
864.0
Admin
Oper
Interface State
State
--------- ------ ----------- ---------- ---------- ------ ------
Gi1/0/1
auto
off
Gi1/0/2
auto
off
Gi1/0/3
auto
off
Gi1/0/4
off
off
Gi1/0/5
off
off
Gi1/0/6
off
off
Gi1/0/7
auto
off
Gi1/0/8
auto
off
Gi1/0/9
auto
on
Gi1/0/10
auto
on
Gi1/0/11
auto
on
Gi1/0/12
auto
on
Gi1/0/13
auto
errdisable
<output truncated>
In the previous example:
The Gi1/0/1 port is shut down, and policing is not configured.
The Gi1/0/2 port is shut down, but policing is enabled with a policing action to generate a syslog
message.
The Gi1/0/3 port is shut down, but policing is enabled with a policing action is to shut down the port.
Device detection is disabled on the Gi1/0/4 port, power is not applied to the port, and policing is
disabled.
Device detection is disabled on the Gi1/0/5 port, and power is not applied to the port, but policing
is enabled with a policing action to generate a syslog message.
Device detection is disabled on the Gi1/0/6 port, and power is not applied to the port, but policing
is enabled with a policing action to shut down the port.
The Gi1/0/7 port is up, and policing is disabled, but the switch does not apply power to the connected
device.
The Gi1/0/8 port is up, and policing is enabled with a policing action to generate a syslog message,
but the switch does not apply power to the powered device.
The Gi1/0/9 port is up and connected to a powered device, and policing is disabled.
The Gi1/0/10 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message. The policing action does not take effect because the real-time
power consumption is less than the cutoff value.
The Gi1/0/11 port is up and connected to a powered device, and policing is enabled with a policing
action to generate a syslog message.
manuals search engine
Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
0.0
0.0
Remaining
(Watts)
---------
0.0
370.0
1.0
Admin
Oper
Police
Police
none
n/a
log
n/a
errdisable n/a
none
n/a
log
n/a
errdisable n/a
none
n/a
log
n/a
none
n/a
log
ok
log
log
errdisable ok
errdisable n/a
Cutoff Oper
Power
Power
n/a
0.0
5.4
0.0
5.4
0.0
n/a
0.0
5.4
0.0
5.4
0.0
n/a
0.0
5.4
0.0
n/a
5.1
5.4
4.2
5.4
5.9
5.4
4.2
5.4
0.0
OL-21522-02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 3750-x

Table of Contents