Table 2-46
show power inline Field Descriptions
Field
Description
Available
The total amount of configured power
Used
The amount of configured power that is allocated to PoE ports in watts.
Remaining
The amount of configured power in watts that is not allocated to ports in the
system. (Available – Used = Remaining)
Admin
Administration mode: auto, off, static.
Oper
Operating mode:
Power
The maximum amount of power that is allocated to the powered device in watts.
This value is the same as the value in the Cutoff Power field in the show power
inline police command output.
Device
The device type detected: n/a, unknown, Cisco powered-device, IEEE
powered-device, or the name from CDP.
Class
The IEEE classification: n/a or a value from 0 to 4.
Max
The maximum amount of power allocated to the powered device in watts.
AdminPowerMax
The maximum amount power allocated to the powered device in watts when the
switch polices the real-time power consumption. This value is the same as the
Max field value.
AdminConsumption
The power consumption of the powered device in watts when the switch polices
the real-time power consumption. If policing is disabled, this value is the same
as the AdminPowerMax field value.
1. The configured power is the power that you manually specify or that the switch specifies by using CDP power negotiation or
the IEEE classification, which is different than the real-time power that is monitored with the power sensing feature. The
configured power values on a Catalyst 3750-E or 3560-E switch is the same as the actual power values on a Catalyst 3750 or
3560 switch.
This is an example of output from the show power inline consumption command on all PoE switch
ports:
Switch> show power inline consumption
Interface
Consumption
Configured
---------- -----------
Gi3/0/1
NO
Gi3/0/2
NO
Gi3/0/3
NO
Gi3/0/4
NO
Gi3/0/5
NO
Gi3/0/6
NO
Gi3/0/7
NO
Gi3/0/8
NO
manuals search engine
on—The powered device is detected, and power is applied.
off—No PoE is applied.
faulty—Device detection or a powered device is in a faulty state.
power-deny—A powered device is detected, but no PoE is available, or the
maximum wattage exceeds the detected powered-device maximum.
Admin
Consumption (Watts)
-------------------
0.0
0.0
0.0
0.0
0.0
0.0
0.0
0.0
Catalyst 3750-X and 3560-X Switch Command Reference
show power inline
1
on the PoE switch in watts (W).