Item
Set a relay station of the own network to send data to a station on another
network by transient transmission. Up to 64 communication paths can be set.
Set routing parameters as shown below.
Target Network No.
Ex.
Relay Network No.
Relay Station No.
*1
Routing parameters are not required for stations (such as head modules) that do not support these parameters.
Communications with other networks are performed according to the routing parameters set for the master station.
● Transient transmission range
Communications can be made with stations up to eight networks apart (number of relay stations: 7).
● Setting for stations that do not perform transient transmission to other networks
Routing parameters are not required for stations that do not perform transient transmission to other networks; however,
setting the same routing parameters to all stations is recommended.
It is recommended to set the same routing parameters as
and
since they pass through the same relay station.
Note that routing parameters are not required for stations (such as head modules) that do not support these parameters.
Communications with other networks are performed according to the routing parameters set for the master station.
120
Description
Setting to transmit data to network number ● by transient transmission
To send data to the network No.
data passes through the station with the own network No.
No routing parameter setting is required for
network No.
because the module of
network No.
is mounted on the relay station.
Network No.
(Relay station)
Network No.
(Relay station)
can communicate by the same routing parameters,
,
and station No.
Station that needs
*1
routing parameters
Network No.
Station which does not perform
transient transmission
Network No.
for
Setting range
1 to 239 (Default: Blank)
.
1 to 239 (Default: Blank)
0 to 120 (Default: Blank)
.