Error code
Constant link scan time setting error
D263
H
(CCPASET)
D264
Station No. range error (CCPASET)
H
D265
Station No. already in use (CCPASET)
H
Slave station setting information error
D266
H
(CCPASET)
D267
Station type error (CCPASET)
H
Device range assignment error
D268
H
(CCPASET)
Target station type error (REMFR/
D269
H
REMTO)
Target station No. error (REMFR/
D26A
H
REMTO)
Network No. error (CCPASET
D26B
H
execution station)
Station No. error (CCPASET execution
D26C
H
station)
Mode error (CCPASET execution
D26D
H
station)
Operation setting error (CCPASET
D26E
H
execution station)
Submaster station No. error
D26F
H
(CCPASET execution station)
Submaster station setting error
D270
H
(CCPASET execution station)
Submaster station setting error
D271
H
(CCPASET execution station)
Submaster station setting error
D272
H
(CCPASET execution station)
448
Error
• Correct the value in Constant link scan time (control data), and retry the
operation.
• If this error persists, please consult your local Mitsubishi representative.
• Correct the value in the station No. (setting data) within 1 to 120, and retry
the operation.
• If this error persists, please consult your local Mitsubishi representative.
• Set a unique value in the station No. (setting data), and retry the
operation.
• If this error persists, please consult your local Mitsubishi representative.
• Correct the value in the slave station setting information (setting data),
and retry the operation.
• If this error persists, please consult your local Mitsubishi representative.
• Correct the value in the station type (setting data), and retry the operation.
• If this error persists, please consult your local Mitsubishi representative.
• Correct the value in the offset or the size of the link device in the slave
station(s) (setting data), and retry the operation.
• If this error persists, please consult your local Mitsubishi representative.
Set the target station number specified using the REMFR or REMTO
instruction to the station number of the intelligent device station or remote
device station.
Return the target station of the REMFR or REMTO instruction.
Set any of 1 to 239 to Switch 1 (network No.) in the intelligent function
module switch setting of the master/local module.
• To start the master/local module as a master station, set 0 to Switch 2 in
the intelligent function module switch setting.
• To start the master/local module as a local station, set Switch 2 in the
intelligent function module switch setting within 3101
31FF
• To start the master/local module as a submaster station, set Switch 2 in
the intelligent function module switch setting of the module within 4101
4178
• Check the serial number (first five digits) of the master/local module to
check if the module supports the function. If not, replace the module with
the one with the latest version.
Set 0 to Switch 3 in the intelligent function module switch setting of the
master/local module.
• To start the master/local module as a master station, set 0 or 2 for Switch
4 in the intelligent function module switch setting of the module.
• To start the master/local module as a local station, set 0 for Switch 4 in the
intelligent function module switch setting of the module.
• To start the master/local module as a submaster station, set 0 or 4 for
Switch 4 in the intelligent function module switch setting of the module.
• If this error persists, please consult your local Mitsubishi representative.
When executing the CCPASET instruction, set a submaster station number
in Slave station setting information (control data) within 1 to 120.
When executing the CCPASET instruction, set one submaster station in the
station type in Slave station setting information (control data).
When executing the CCPASET instruction, do not set a submaster station
number in Reserved station specification (control data).
When executing the CCPASET instruction, do not set a submaster station
number in Error invalid station setting (control data).
Action
.
H
.
H
to 3178
, and
H
H
to
H

Advertisement

Table of Contents
loading

Table of Contents