(d) CCPASET instruction execution timing
• When completed
Sequence scan
Start contact
Completion device
Own station CPU
(Device specified in (D))
Completion status indication
device (Device of (D)+1)
Master/local module
• When failed
Sequence scan
Start contact
Completion device
Own station CPU
(Device specified in (D))
Completion status indication
device (Device of (D)+1)
Completion status
(Device of (S1)+0)
Master/local module
(3) Checking error details
If the dedicated instruction fails, error details can be checked by either of the following methods:
(a) In GX Works2
Error details can be checked using the CC-Link IE Field Network diagnostics. (
(b) Using devices
Completion status indication device ((D)+1) turns on, and an error code is stored in Completion status ((S1)+0)
of the control data.
According to the error code, check the error details and take a corrective action.
(
Page 439, Section 12.5)
370
CCPASET
0
END
0
OFF
Parameter setting
CCPASET
0
END
0
Parameter setting error
END
0
END
0
END
1 scan
END
0
END
0
1 scan
0
END
END
0
END
Error code
Page 206, CHAPTER 9)