hit counter script

Mitsubishi Electric QJ71GF11-T2 User Manual page 297

Melsec-q series cc-link ie field network master/ local module
Table of Contents

Advertisement

(a) Control data
Device
Item
Abnormal end
(S1)+0
type
(S1)+1
Completion status
Own station's
(S1)+2
channel
Send station's
(S1)+3
channel
Send station's
(S1)+4
network No.
Send station
(S1)+5
number
(S1)+6
(S1)+7
Arrival monitoring
(S1)+8
time
Received data
(S1)+9
length
(S1)+10
(S1)+11
Clock set flag
(S1)+12 to
Clock data of
(S1)+15
abnormal end
Setting data
b15
to
0
1) Abnormal end type (bit 7)
Specify the data set status in case of abnormal end.
0: After (S1)+11, no data is set for abnormal end.
1: Data at the time of abnormal end is set in the area starting from
(S1)+11.
The status of when the instruction is ended is stored.
0: Normal
Values other than 0: Error (
Specify the channel of the own station where the received data is stored
(
Page 241, Section 10.2.2 (1))
The channel used by the send station is stored.
The network No. of the send station is stored.
1 to 239: Network No.
The station No. of the send station is stored.
Master station: 125 (7D
)
H
Local station, intelligent device station, submaster station: 1 to 120
Unused
Unused
Specify the monitoring time until instruction completion.
If processing is not completed within the time, the instruction is
abnormally terminated.
0: 10 seconds
1 to 32767: 1 to 32767 seconds
The received data size in (D1) to (D1)+n is stored.
1 to 960: Received data size (words)
Unused
The valid or invalid status of data after (S1)+12 is stored.
(Data is stored when "1: Data at the time of abnormal end is set in the
area starting from (S1)+11." is set in the abnormal end type in (S1)+0.)
The stored data is not cleared even if the dedicated instruction is
normally completed.
0: Invalid
1: Valid
Clock data of abnormal end are stored in BCD format.
(Data is stored when "1: Data at the time of abnormal end is set in the
area starting from (S1)+11." is set in the abnormal end type in (S1)+0.)
The stored data is not cleared even if the dedicated instruction is
normally completed.
b15
Month (01
to 12
(S1)+12
H
Hour (00
to 23
(S1)+13
H
Second (00
to 59
(S1)+14
H
(S1)+15
Year (00
to 99
), first 2 digits
H
H
CHAPTER 10 DEDICATED INSTRUCTIONS
b7
to
b0
1
0
Page 439, Section 12.5)
b8 b7
b0
)
H
Year (00
to 99
), last 2 digits
H
H
)
Day (01
to 31
)
H
H
H
)
Minute (00
to 59
)
H
H
H
Day of week (00
to 06
)
H
H
00
(Sun.) to 06
(Sat.)
H
H
Setting range
Set by
0000
H
User
0080
H
System
1 and 2
User
System
System
System
0
User
0
User
0 to 32767
User
System
0
User
System
System