Power Supplies in the Cisco ASR 1002-X Router
Table 75: +24 VDC Output Voltage Alarm Threshold Ranges
Output
12 V
3.3 V
• Temperature—If a fan fails, the power supply meets the functional requirements specified in above
table. The calculated MTBF does not apply above 55°C with less than two fans. However, all the
component stress remains within the manufacturer's specified rating.
• Thermal shutdown—The +24 VDC power supply shuts down to protect its components due to excessive
internal temperature. The +24 VDC power supply then automatically restarts after the internal temperature
returns to a safe operating level.
Power Cords Supported by the Cisco ASR 1002-X Router
The following table lists the power cords that are supported by the Cisco ASR 1002-X Router.
Table 76: Power Cords Supported by the Cisco ASR 1002-X Router
Power Cord Item Number
CAB-AC-RA
CAB-ACA-RA
CAB-ACB10A-RA
CAB-ACB16A-RA
CAB-ACC-RA
CAB-ACE-RA
CAB-ACI-RA
CAB-ACR-RA
CAB-ACS-RA
CAB-ACU-RA
CAB-IND-RA
CAB-JPN-RA
Cisco ASR 1000 Series Router Hardware Installation Guide
330
Cisco ASR 1002-X Router Overview and Installation
Minimum
10.0-11.2 V
2.6 – 3.0 V
Description
Power Cord, 110 V, Right Angle
Plug, Power Cord, Australia, 10 A, Right Angle
Power Cord, Brazil, Right Angle, 10 A
Power Cord, Brazil, Right Angle, 16 A
Power Cord, China, Right Angle
Power Cord, Europe, Right Angle
Power Cord, Italy, Right Angle
Power Cord, Argentina, Right Angle
Power Cord, Switzerland, Right Angle
Power Cord, UK, Right Angle
Power Cord, India, Right Angle
Power Cord, Japan, Right Angle
Maximum
12.8-13.8 V
None