Model Designation and Specifications
Accuracy .........................................+/-0.6°C
Conformity......................................<= 0.06°
Software Output Type.....................Analog (configurable °C, °F, °R, °K)
Ambient Temperature Effect: ........+/- 0.10°C/°C
Type 'T' Thermocouple:
Range Limits...................................-240°C to 370°C (-400°F to 698°F)
Performance Range.........................-100 to 370°C
Accuracy .........................................+/-0.5°C
Conformity......................................<= 0.06°
Software Output Type.....................Analog (configurable °C, °F, °R, °K)
Ambient Temperature Effect: ........+/- 0.07°C/°C
Type 'E' Thermocouple:
Range Limits...................................-185°C to 1000°C (-300°F to 1830°F)
Performance Range.........................0 to 1000°C
Accuracy .........................................+/-0.5°C
Conformity......................................<= 0.06°
Software Output Type.....................Analog (configurable °C, °F, °R, °K)
Ambient Temperature Effect: ........+/- 0.07°C/°C
Type 'S' Thermocouple:
Range Limits...................................-18°C to 1650°C (0°F to 3000°F)
Performance Range.........................200 to 1650°C
Accuracy .........................................+/-0.7°C
Conformity......................................<= 0.06°
Software Output Type.....................Analog (configurable °C, °F, °R, °K)
Ambient Temperature Effect: ........+/- 0.14°C/°C
Type 'R' Thermocouple:
Range Limits...................................-18°C to 1610°C (0°F to 2930°F)
Performance Range.........................200 to 1610°C
Accuracy .........................................+/-0.7°C
Conformity......................................<= 0.06°
Software Output Type.....................Analog (configurable °C, °F, °R, °K)
Ambient Temperature Effect: ........+/- 0.15°C/°C
Type 'B' Thermocouple:
Range Limits...................................-18°C to 1815°C (0°F to 3300°F)
Performance Range.........................800 to 1815°C
Accuracy .........................................+/-0.7°C
Conformity......................................<= 0.06°
Software Output Type.....................Analog (configurable °C, °F, °R, °K)
Ambient Temperature Effect: ........+/- 0.15°C/°C
Type 'N' Thermocouple:
Range Limits...................................-200°C to 1300°C (-325°F to 2370°F)
Performance Range.........................0 to 1300°C
Accuracy .........................................+/-0.5°C
Conformity......................................<= 0.06°
Software Output Type.....................Analog (configurable °C, °F, °R, °K)
Ambient Temperature Effect: ........+/- 0.10°C/°C
Type DIN 43760/ IEC 751 RTD (à = 0.003850):
Range Limits...................................-185°C to 622°C (-300°F to 1152°F)
Accuracy .........................................+/-0.4 °C
Software Output Type.....................Analog (configurable °C, °F, °R, °K)
Ambient Temperature Effect: ........+/- 0.04°C/°C
14-8
UM353-1
March 2003