DB31, ...
DBX94.2
Run-up completed
Edge evaluation: No
Signal state 1
The actual speed value has reached the speed tolerance band specified via p2164 after a new speed
setpoint specification and has not left the band for the duration of p2166.
Any subsequent speed fluctuations, also outside the tolerance band, e.g. due to load changes, will
not affect the interface signal.
Signal state 0
The run-up procedure is still active after the speed setpoint has been changed.
Corresponding to ...
DB31, ... DBX94.6 ("n
DB31, ... DBX94.3 ("|M
Additional references ● SINUMERIK Commissioning Manual IBN CNC: NCK, PLC, Drive
● SIMATIC S120 List Manual
DB31, ...
DBX94.3
|M
Edge evaluation: No
Signal state 1
The current torque utilization is below the torque utilization threshold (torque threshold 2, p2194).
The run-up procedure is completed, the drive is in the steady state and the torque setpoint |M
does not exceed the threshold torque M
The torque threshold characteristic is speed-dependent.
During the run-up, DB31, ... DBX94.3 (|M
run-up has been completed (DB31, ... DBX94.2 == 1) and the signal interlocking time for the threshold
torque has expired.
Signal state 0
The torque setpoint |M
A motor overload can be determined via the interface signal. An appropriate response can then be
initiated in the PLC user program.
Remark
DB31, ... DBX94.3 = MELDW.1
Additional references ● SINUMERIK Commissioning Manual IBN CNC: NCK, PLC, Drive
● SIMATIC S120 List Manual
DB31, ...
DBX94.4
|n
Edge evaluation: No
Signal state 1
The actual speed value n
Signal state 0
The actual speed value is greater than the threshold minimum speed n
Remark
DB31, ... DBX94.4 = MELDW.2
Additional references Commissioning Manual IBN CNC: NCK, PLC, Drive
DB31, ...
DBX94.5
|n
Edge evaluation: No
Signal state 1
The actual speed value n
Signal state 0
The actual speed value n
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Signal(s) updated: Cyclically
= n
act
| = M
D
| < M
d
dx
Signal(s) updated: Cyclically
| is larger than the threshold torque M
d
| < n
act
min
Signal(s) updated: Cyclically
act
| < n
act
x
Signal(s) updated: Cyclically
act
act
19.1 Various interface signals and functions (A2)
")
set
")
dx
.
dx
|< M
) == 1. The interface signal is not updated until the
d
dx
is less than n
(speed threshold value 3, p2161).
min
is less than n
(speed threshold value 2, p2155).
x
is greater than the threshold speed n
Z1: NC/PLC interface signals
.
dx
.
min
.
x
| drive
d