DB31, ...
DBX76.4
Path axis
Edge evaluation: no
Signal state 1 or
The axis is involved in the path (path axis).
edge change
Note
0 → 1
In conjunction with SERUPRO in status "Target block found", the signal refers to the status of the
axis in the target block.
Signal state 0 or
The axis is not involved in the path.
edge change
1 → 0
19.7
Axis types, coordinate systems, frames (K2)
19.7.1
Signals to axis/spindle (DB31, ...)
DB 31, ...
DBX3.0
External Zero Offset
Edge evaluation: no
Signal state 1 or
The preselected value of the external work offest of an axis is used as the new value for calculating
edge change
the total work offset between the basic and the workpiece coordinate systems.
0 → 1
Signal state 0 or
The preselected value of the external work offset of an axis is not used as the new value for calculating
edge change
the total work offset between the basic and workpiece coordinate systems. The previous value is still
1 → 0
valid.
Signal irrelevant
$AA_ETRANS[axis] equals zero for all axes.
for ...
Special cases,
Signal zero after ramp-up (power ON).
errors, ......
Corresponding to ....
$AA_ETRANS[axis]
19.8
Emergency stop (N2)
19.8.1
Signals to NC (DB10)
DB10
DBX56.1
Emergency stop
Edge evaluation: No
Signal state 1 or
The NC is brought into the emergency stop state and the emergency stop sequence in the NC is
edge change
started.
0 → 1
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Signal(s) updated: cyclic
Signal(s) updated:
Signal(s) updated: Cyclically
Z1: NC/PLC interface signals
19.8 Emergency stop (N2)
1629