V1: Feedrates
17.4 Feedrate control
MD22240 $MC_AUXFU_F_SYNC_TYPE (output time of F functions)
The output is suppressed in the default setting (MD22240 = 3), because drops in velocity can
occur through the output of F functions to the NC/PLC interface in continuous-path mode.
For more information, see Description of Functions "H2: Auxiliary function outputs to PLC
(Page 377)".
Reset behavior
The behavior after the end of program or NC reset is specified by the machine data:
MD22410 $MC_F_VALUES_ACTIVE_AFTER_RESET (F function is active even after reset)
Value
0
1
17.4
Feedrate control
17.4.1
Feedrate disable and feedrate/spindle stop
Function
The "Feed disable" or "Feed/spindle stop" brings the axes to a standstill with adherence to the
braking characteristics and the path contour (exception: G33 block).
Channel-specific feedrate disable
The NC/PLC interface signal:
DB21, ... DBX6.0 (feedrate disable)
stops all axes (geometry and auxiliary axes) of a channel in all modes.
Effectiveness of the channel-specific feedrate disable:
● With active G33, G34, G35:
● With active G63:
● With active G331, G332:
"Feed stop" for geometry axes in JOG mode
The NC/PLC interface signals:
DB21, ... DBX12.3 (feed stop for geometry axis 1)
DB21, ... DBX16.3 (feed stop for geometry axis 2)
DB21, ... DBX20.3 (feed stop for geometry axis 3)
stop the relevant geometry axes if a channel in JOG mode.
1334
Meaning
The default values are effective after NC reset.
The last programmed FA values are effective after NC reset.
Not effective
Effective
Effective
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
Basic Functions