19.6
Mode group, channel, program operation, reset response (K1)
19.6.1
Signals to mode group (DB11)
DB11
DBX0.0
AUTOMATIC mode
Edge evaluation: No
Signal state 1 or
AUTOMATIC mode is selected by the PLC program.
edge change
0 → 1
Signal state 0 or
AUTOMATIC mode is not selected by the PLC program.
edge change
1 → 0
Signal irrelevant
DB11 DBX0.4 (operating mode, changeover inhibit) = 1
for ...
Corresponding to ...
DB11 DBX6.0 (active AUTOMATIC mode)
DB11
DBX0.1
MDA mode
Edge evaluation: No
Signal state 1 or
MDA mode is selected by the PLC program.
edge change
0 → 1
Signal state 0 or
MDA mode is not selected by the PLC program.
edge change
1 → 0
Signal irrelevant
DB11 DBX0.4 (operating mode, changeover inhibit) = 1
for ...
Corresponding to ...
DB11 DBX6.1 (active MDA mode)
DB11
DBX0.2
JOG mode
Edge evaluation: No
Signal state 1 or
JOG mode is selected by the PLC program.
edge change
0 → 1
Signal state 0 or
JOG mode is not selected by the PLC program.
edge change
1 → 0
Signal irrelevant
DB11 DBX0.4 (operating mode, changeover inhibit) = 1
for ...
Corresponding to ...
DB11 DBX6.2 (active JOG mode)
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
19.6 Mode group, channel, program operation, reset response (K1)
Signal(s) updated: Cyclically
Signal(s) updated: Cyclically
Signal(s) updated: Cyclically
Z1: NC/PLC interface signals
1601