certain spindle definitions (speed or cutting speed, feedrate type) can be taken from the part
program, synchronized action and FC18 and entered in the corresponding setting data:
Bit 4 = 1
Bit 8 = 1
Bit 10 = 1
Speed default
Speed defaults from part program, FC18 or synchronized actions are written to the following
setting data from all the usual sources:
SD43200 $SA_SPIND_S (speed for spindle start via PLC interface)
The setting data can be written to as follows:
● Through speed programming
● Through direct programming in the part program
● Through HMI software
Note
The setting data is written immediately and asynchronously to part-program execution.
Basic Functions
Function Manual, 01/2015, 6FC5397-0BP40-5BA2
The programmed speed S... including speed setpoints via FC18 and synchronized
actions are accepted in the following setting data:
SD43200 $SA_SPIND_S (speed for spindle start via PLC interface)
Programmed S values that are not programmed speed values are not accepted in the
SD. These include, for example:
● S value at constant cutting speed (G96, G961)
● S value for rotation-related dwell time (G4)
The programmed cutting speed S... including setpoints via FC18 and synchronized
actions are accepted in the following setting data:
SD43202 $SA_SPIND_CONSTCUT_S (cutting speed for spindle start via PLC inter‐
face)
Programmed S values that are not programmed cutting speed values are not accepted
in the SD. These include, for example:
● S value outside the constant cutting speed (G96, G961, G962)
● S value for rotation-related dwell time (G4)
For the master spindle, the value of the 15th G group (feedrate type) is accepted in the
following setting data SD43206 $SA_SPIND_SPEED_TYPE.
SD43206 $SA_SPIND_SPEED_TYPE (spindle speed type for spindle start via PLC
interface)
For all other spindles, the value in SD43206 remains unchanged.
S1: Spindles
16.7 Programming