Chapter 2 Catalyst 3750-X and 3560-X Cisco IOS Commands
show env
Syntax Description
Command Modes
Command History
OL-21522-02
Downloaded from
www.Manualslib.com
Use the show env user EXEC command to display fan, temperature, redundant power system (RPS)
availability, and power information for the switch or the switch stack.
show env {all | fan | power [all | switch [switch-number]] | rps | stack [switch-number] |
temperature [status]} [ | {begin | exclude | include} expression]
all
Display the fan and temperature environmental status and the status of the internal
power supplies and the RPS.
fan
Display the switch fan status.
power
Display the switch internal power status.
power all
(Optional) Display the status of all the internal power supplies in a standalone
switch when the command is entered on the switch or in all the stack members
when the command is entered on the stack master.
power switch
(Optional) Display the status of the internal power supplies for each switch in the
[switch-number]
stack or for the specified switch. The range is 1 to 9, depending on the switch
member numbers in the stack.
These keywords are available only on Catalyst 3750-E switches.
rps
Display whether a redundant power system is connected to a Catalyst 3750-E or
Catalyst 3750 switch in the stack as follows:
Catalyst 3750-E—Cisco Redundant Power System 2300, also referred to as
•
the RPS 2300.
Catalyst 3750 switch—the RPS 2300 or Cisco RPS 675 Redundant Power
•
System, also referred to as the RPS 675.
Note
stack
Display all environmental status for each switch in the stack or for the specified
[switch-number]
switch. The range is 1 to 9, depending on the switch member numbers in the stack.
This keyword is available only on stacking-capable switches.
temperature
Display the switch temperature status.
temperature
(Optional) Display the switch internal temperature (not the external temperature)
status
and the threshold values.
| begin
(Optional) Display begins with the line that matches the expression.
| exclude
(Optional) Display excludes lines that match the expression.
| include
(Optional) Display includes lines that match the specified expression.
expression
Expression in the output to use as a reference point.
User EXEC
Release
12.2(53)SE2
manuals search engine
Catalyst 3750-X and 3560-X switches do not connect to redundant power
systems.
Modification
This command was introduced.
Catalyst 3750-X and 3560-X Switch Command Reference
show env
2-571