copy logging onboard
copy logging onboard
Syntax Description
Defaults
Command Modes
Catalyst 3750-X and 3560-X Switch Command Reference
2-130
Downloaded from
www.Manualslib.com
Use the copy logging onboard privileged EXEC command on the switch stack or on a standalone switch
to copy on-board failure logging (OBFL) data to the local network or a specific file system.
copy logging onboard module stack-member destination
module
Specify the stack member number. If the switch is a standalone switch, the switch
stack-member
number is 1. If the switch is in a stack, the range is 1 to 9, depending on the switch
member numbers in the stack.
This keyword is supported only on on stacking-capable switches.
destination
Specify the location on the local network or file system to which the system
messages are copied.
For destination, specify the destination on the local or network file system and the
filename. These options are supported:
The syntax for the local flash file system:
•
flash[number]:/filename
Use the number parameter to specify the stack member number of the stack
master. The range for number is 1 to 9.
The syntax for the FTP:
•
ftp://username:password@host/filename
The syntax for an HTTP server:
•
http://[[username:password]@]{hostname | host-ip}[/directory]/filename
The syntax for the NVRAM:
•
nvram:/filename
The syntax for the null file system:
•
null:/filename
The syntax for the Remote Copy Protocol (RCP):
•
rcp://username@host/filename
The syntax for the switch file system:
•
system:filename
The syntax for the temporary file system:
•
tmpsys:/filename
The syntax for the TFTP:
•
tftp:[[//location]/directory]/filename
This command has no default setting.