Mitsubishi Electric NZ2GF2B-60TCTT4 User Manual page 170

Cc-link ie field network temperature control module
Table of Contents

Advertisement

(c) Time unit setting
1.
Set "Method selection" to "Param write" of the control mode to be used.
"CC IE Field Configuration" windowSelect the temperature control module from "List of
stations"[CC IE Field Configuration][Online][Parameter Processing of Slave Station]
2.
Set "CH Setting change rate limiter unit time setting".
Operation of when individual setting is selected
Ex.
Temperature process
Set value
(SV) 1
168
CH□ Setting change rate limiter (temperature rise)
(address: 108H, 138H, 168H, 198H)
value (PV)
Set value
(SV) 2
Default value of CH□ Setting change rate limiter
unit time setting (address: 109H, 139H, 169H, 199H)
CH□ Setting change rate limiter (temperature drop)
(address: 1C8H, 1CDH, 1D2H, 1D7H)
Set value
(SV) 3
Time