(17)CH Number of moving averaging (address: 10EH, 13EH, 16EH, 19EH)
For each channel, set the number of moving averaging to be performed to temperature process values (PV).
For details on the moving averaging process to temperature process values (PV), refer to the following.
Page 129, Section 8.1.3
This setting is enabled only when Enable (0) is set to Moving averaging process setting (address: 1H. b3). If
Disable (1) is set to Moving averaging process setting (address: 1H. b3), this setting is ignored.
For details on Moving averaging process setting (address: 1H. b3), refer to the following.
Page 310, Appendix 3 (1) (d)
(a) Setting range
2 to 10 (times)
(b) Enabling the setting
To enable the setting, turn off and on Initial data setting request flag (RY9) while the operations of all channels
are stopped.
(c) Default value
2 (times) are set in all channels as default values.
(18)CH Control response parameter (address: 10FH, 13FH, 16FH, 19FH)
Standard
Heating-cooling
In the simple two-degree-of-freedom PID control, select the response speed to the change of the set value (SV)
from the following three levels: Slow, Normal, and Fast.
For details on the simple two-degree-of-freedom, refer to the following.
Page 165, Section 8.3.8
(a) Setting range
Setting
Setting value
contents
Set Slow when reducing an overshoot and undershoot to the change of the set value (SV). However, the settling time is
0
Slow
the longest of the three settings.
1
Normal
Normal has features between Slow and Fast.
Set Fast when speeding up the response to the change of the set value (SV). However, an overshoot and undershoot is
2
Fast
the largest of the three settings.
Temperature process value (PV)
Set value (SV) 2
Change
Set value (SV) 1
Description
Fast
Set value (SV) change point
Normal
Slow
Time
APPENDICES
A