13.4 Universal serial interface (USS) communication
13.4.2

Requirements for using the USS protocol

The four USS instructions use two function blocks (FBs) and two functions (FCs) to support
the USS protocol. One USS_Port_Scan instance data block (DB) is used for each USS
network. The USS_Port_Scan instance data block contains temporary storage and buffers
for all drives on that USS network. The USS instructions share the information in this data
block.
All drives (up to 16) connected to a single RS485 port are part of the same USS network. All
drives connected to a different RS485 port are part of a different USS network. Each USS
network is managed using a unique data block. All instructions associated with a single USS
network must share this data block. This includes all USS_Drive_Control, USS_Port_Scan,
USS_Read_Param, and USS_Write_Param instructions used to control all drives on a single
USS network.
The USS_Drive_Control instruction is a Function Block (FB). When you place the
USS_Drive_Control instruction into the program editor, you will be prompted by the "Call
options" dialog to assign a DB for this FB. If this is the first USS_Drive_Control instruction in
this program for this USS network, then you can accept the default DB assignment (or
change the name if you wish) and the new DB is created for you. If however this is not the
first USS_Drive_Control instruction for this channel, then you must use the drop-down list in
the "Call options" dialog to select the DB name that was previously assigned for this USS
network.