(2) Setting the reference position
The reference position can be set as shown below by setting the "#2037 G53ofs".
(Example 1) To set the reference
position to the same position as
the basic machine coordinate
system zero point.
(Example 2)To set the reference
position at a position 200.0mm to
the + side from the basic machine
coordinate zero point.
(To set the basic machine
coordinate system zero point
300.0mm front of the absolute
position origin point.)
7.1 Adjusting the Absolute Position Detection System
Reference
"G53ofs" = 0
position
Basic machine
"#2 Zero-P"
coordinate system
zero point
"G53ofs" = 200.0
Reference position
Basic machine
coordinate
"#2 Zero-P" = 300.0
system
zero point
M700VS Series Setup Manual
Absolute position
origin point
(Mechanical basic
position or electrical
basic position)
Absolute
position
origin point
(Mechanical
basic position
or electric
basic position)
85