【#2282】 SV082 SSF5 Servo function 5
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F-C : dis Digital signal input selection
0: No signal
1: Safety observation function door state signal
2: Battery box voltage drop warning (It is not available for MDS-D-SVJ3 Series.)
3 to F: Setting prohibited
bit B-A : dos3 Digital signal output 3 selection
bitB,A=
00: Disable
01: Setting prohibited
10: Contactor control signal output (For MDS-D-SVJ3)
11: Setting prohibited
bit 9-8 : dos2 Digital signal output 2 selection
bit9,8=
00: Disable
01: Specified speed output
10: Setting prohibited
11: Setting prohibited
bit 7-3 :
Not used. Set to "0".
bit 2 : ccu Lost motion overshoot compensation compensation amount setting
increment
0: Stall current %
bit 1 : lmc3 Lost motion compensation type 3
Set this when protrusion at a quadrant change is too big.
0: Stop
Related parameters: SV016, SV041, SV085, SV086
bit 0 :
Not used. Set to "0".
1: Stall current 0.01%
1: Start
M700VS Series Setup Manual
Appendix 1.4 Servo Parameters
lmc3
ccu
dos2
dos3
dis
341