MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#8909(PR)】 Aut/Manual switch
Select the counter display method on Monitor screen.
0: "AUTO/MDI" and "Manual" display is switched by the mode selection switch.
1: Display AUTO/MDI counter only.
2: Display Manual counter only.
3: Display the enlarged counter of "#8901 Counter type 1".
(Note) This parameter is disabled when "#11019 2-system display (2-part system simultaneous
【#8910】 Edit undo
Set whether to enable the Undo function during program edit on the Monitor screen or Edit screen.
0: Disable
1: Enable
(Note) This parameter is valid only with M700VW/M700VS/M700/M70V Series.
【#8913】 Touch panel sense
Set the sensibility of the touch panel.
The smaller the setting value is, the more sensitive the panel will be.
(1: sensitive, 4: insensitive)
When set to 0, the sensibility will be the same as when the standard setting of 2 is applied.
(Note) This parameter is available for M700VS/M70V/M70 Series.
---Setting range---
0 to 4
【#8914】 Auto Top search
Select the operation method for restart search type 2.
0: It is necessary to set the top search position arbitrarily.
1: The restart search is executed from O No. that is designated as head.
【#8915】 Auto backup day 1
When the NC power is ON after the designated date was passed over, the automatic backup is
executed.
When "-1" is set to "Auto backup day 1", the automatic backup is executed every turning NC power
ON.
When "0" is set to all on "Auto backup day 1" to "4", the automatic backup is not executed.
It is possible to specify the designated date up to 4 days for a month.
---Setting range---
-1 to 31("-1" can be set for "Auto backup day 1" only.)
【#8916】 Auto backup day 2
When the NC power is ON after the designated date was passed over, the automatic backup is
executed.
When "-1" is set to "Auto backup day 1", the automatic backup is executed every turning NC power
ON.
When "0" is set to all on "Auto backup day 1" to "4", the automatic backup is not executed.
It is possible to specify the designated date up to 4 days for a month.
---Setting range---
-1 to 31("-1" can be set for "Auto backup day 1" only.)
【#8917】 Auto backup day 3
When the NC power is ON after the designated date was passed over, the automatic backup is
executed.
When "-1" is set to "Auto backup day 1", the automatic backup is executed every turning NC power
ON.
When "0" is set to all on "Auto backup day 1" to "4", the automatic backup is not executed.
It is possible to specify the designated date up to 4 days for a month.
---Setting range---
-1 to 31("-1" can be set for "Auto backup day 1" only.)
178
display)" is set to "1" or "2".

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents