【#1229】 set01
bit0: Subprogram interrupt
Select the type of the user macro interrupt.
0: Macro type user macro interrupt
1: Sub-program type user macro interrupt
bit1: Accurate thread cutting E
Select what the address E specifies in inch screw cutting.
0: Number of threads per inch
1: Precision lead
bit2: Radius compensation type B (for M system only)
Select the method of the arithmetic processing for the intersection point when the start-up or cancel
command is operated during radius compensation.
0: The processing does not handle the start-up or cancel command block: handle the offset vector
1: The processing is executed for the intersection point between the command block and the next
bit2: Nose R compensation type B (for L system only)
Select the method of the arithmetic processing for the intersection point when the start-up or cancel
commands are operated during nose R or radius compensation.
0: The processing does not handle the start-up or cancel command block: handle the offset vector
1: The processing is executed for the intersection point between the command block and the next
bit3: Initial constant surface speed
Select the initial state after the power-ON.
0: Constant surface speed control cancel mode
1: Constant surface speed control mode
bit4: Synchronous tap
Select the operation when ",R" is omitted in G74/G84 tapping cycle.
0: Asynchronous tap
1: Synchronous tap
bit5: Start point alarm
Select the operation when the operation start point cannot be found while executing the next block of
G117.
0: Enables the auxiliary function after the block has been executed.
1: Outputs the program error (P33).
bit6: Grid display selection
Select the grid display type on the servo monitor screen during the dog type reference position
return.
0: Distance between dog OFF and basic point (including a grid mask amount)
1: A value given by reducing a grid mask amount from the distance between dog OFF and basic
【#1230】 set02
bit7: Macro interface input/output for each part system
Select the specification of the macro interface input/output.
0: Shared by all part systems.
1: Used independently by the part systems.
in the direction vertical to that of the command instead.
block.
in the direction vertical to that of the command instead.
block.
point