MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#9409】 DEV3 DC CODE PRTY
Select the DC code type when the DC code method is selected.
0: Not add parity to DC code (DC3 = 13H)
1: Add parity to DC code (DC3 = 93H)
【#9411】 DEV3 DC2/4 OUTPUT
Select the DC code handling when outputting data to the output device.
DC2 / DC4
0: None / None
1: Yes / None
2: None / Yes
3: Yes / Yes
【#9412】 DEV3 CR OUTPUT
Select whether to add the (CR) code just before the EOB (L/F) code during output.
0: Not add
1: Add
【#9413】 DEV3 EIA OUTPUT
Select ISO or EIA code for data output.
In data input mode, the ISO and EIA codes are identified automatically.
0: ISO code output
1: EIA code output
【#9414】 DEV3 FEED CHR.
Set the length of the tape feed to be output at the start and end of the data during tape output.
---Setting range---
0 to 999 (characters)
【#9415】 DEV3 PARITY V
Select whether to perform the parity check for the number of characters in a block at the input of
data.
At the output of data, the number of characters is always adjusted to for the parity check.
0: Not perform parity V check
1: Perform parity V check
【#9416】 DEV3 TIME-OUT (sec)
Set the time out time to detect an interruption in communication.
Time out check will not be executed when set to "0".
---Setting range---
0 to 30 (s)
【#9417】 DEV3 DR OFF
Select whether to enable the DR data check in data I/O mode.
0: Enable
1: Disable
【#9418】 DEV3 DATA ASCII
Select the code of the output data.
0: ISO/EIA code (Depends on whether #9113, #9213, #9313, #9413 or #9513 EIA output
1: ASCII code
【#9419】 DEV3 INPUT TYPE
Select the mode for input (verification).
0: Standard input (Data from the very first EOB is handled as significant information.)
1: EOBs following the first EOB of the input data are skipped until data other than EOB is input.
198
parameter is set up.)