hit counter script

Mitsubishi Electric M700VS Series Setup Manual page 598

Mitsubishi cnc
Table of Contents

Advertisement

P126 Invalid cmnd in high-accuracy
Details
An illegal command was issued during the high-accuracy control mode.
- A G code group 13 command was issued during the high-accuracy control mode.
- Milling, cylindrical interpolation or pole coordinate interpolation was commanded during the high-
accuracy control mode.
Remedy
- Correct the program.
P127 No spec: SSS Control
Details
The SSS control valid parameter has been set although there is no SSS control specification.
Remedy
- Check the specifications. Set "#8090 SSS ON" to "0" when there is no SSS control specification.
P128 Machin condtn select I disable
Details
Machining condition selection I was commanded during the mode where the selection command is
unavailable.
Remedy
- Check the program and see whether any unavailable mode is included during machining condition
selection I. If any, cancel that mode.
P130 2nd M function code illegal
Details
The 2nd miscellaneous function address, commanded in the program, differs from the address set in
the parameters.
Remedy
- Correct the 2nd miscellaneous function address in the program.
P131 No spec: Cnst surface ctrl G96
Details
A constant surface speed control command (G96) was issued though it is out of specifications.
Remedy
- Check the specifications.
- Issue a rotation speed command (G97) instead of the constant surface speed control command
(G96).
P132 Spindle rotation speed S=0
Details
No spindle rotation speed command has been issued.
Remedy
- Correct the program.
P133 Illegal P-No. G96
Details
The illegal No. was specified for the constant surface speed control axis.
Remedy
- Correct the parameter settings and program that specify the constant surface speed control axis.
P134 G96 Clamp Err.
Details
The constant surface speed control command (G96) was issued without commanding the spindle
speed clamp (G92/G50).
Remedy
Press the reset key and carry out the remedy below.
- Check the program.
- Issue the G92/G50 command before the G96 command.
- Command the constant surface speed cancel (G97) to switch to the rotation speed command.
M700VS Series Setup Manual
Appendix 2.12 Program Errors (P)
581

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents