4 Setting the Parameters and Date/Time
Confirm the emergency stop state before carrying out the steps in this chapter.
WARNING

4.1 Selecting the NC System Type

When employing the lathe system, set the parameter as follows.
(1) On the Mainte screen, select [Mainte] and then [Psswd input].
Enter "MPARA" in the setting area and press the INPUT key.
(Note 1) To enter the character "A", press the shift key and then "A" key. Do not press both keys at the same time.
(Note 2) The entered password is displayed as "*****". See below.
(2) Press the cancel key to return to the Mainte screen. Then select [Param].
(3) Select [Param number]. Enter "1007" in the setting area and press the INPUT key.
The screen changes to the base system parameters screen. The cursor moves to the "#1007 System type select"
field.
(4) Enter "1" in the setting area and press the INPUT key. (0: Machining center system 1: Lathe system)
(5) Turn the power OFF and ON.