MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#9427】 DEV3 EIA CODE $
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code
"$".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9428】 DEV3 EIA CODE !
Set the code in hexadecimal, which does not duplicate the existing EIA codes, for the special code
"!".
When output with EIA code, data can be output using the alternate code in which the special ISO
code, not included in EIA, is specified.
---Setting range---
0 to FF (hexadecimal)
【#9501】 DEV4 DEVICE NAME
Set the device name corresponding to the device No.
Set a simple name for quick identification.
---Setting range---
Use alphabet characters, numerals and symbols to set a name within 3 characters.
【#9502】 DEV4 BAUD RATE
Select the serial communication speed.
0: 19200 (bps)
1: 9600
2: 4800
3: 2400
4: 1200
5: 600
6: 300
7: 110
【#9503】 DEV4 STOP BIT
Select the stop bit length used in the start-stop system.
Refer to "#9504 DEV4 PARITY CHECK". At the output of data, the number of characters is always
adjusted to for the parity check.
1: 1 (bit)
2: 1.5
3: 2
【#9504】 DEV4 PARITY CHECK
Select whether to add a parity check bit to the data.
ON
OFF
Start bit
Set this parameter in accordance with the I/O device specifications.
0: Not add a parity bit in I/O mode
1: Add a parity bit in I/O mode
【#9505】 DEV4 EVEN PARITY
Select whether even or odd parity will be used when parity is used. This parameter is ignored when
no parity is added.
0: Odd parity
1: Even parity
200
1character
b1 b2 b3 b4 b5 b6
bn
Data bit
Parity bit
Stop bit