【#2399-2437】 SV199 - SV237
Not used. Set to "0".
【#2438】 SV238 SSCFEED Safety observation Safety speed
Set the machine's safety speed for the safety observation function.
Set this parameter within the following setting ranges.
For linear axis: 2000mm/min or less
For rotary axis: 18000°/min (50r/min) or less
When not using, set to "0".
Related parameters: SV033/bitD, SV113/bitF, SV239
---Setting range---
0 to 18000 (mm/min) or (°/min)
However, when SV033/bitD=1, the setting range is from -32768 to 32767 (100 mm/min) or (100°/
min).
【#2439】 SV239 SSCRPM Safety observation Safety motor speed
Set the motor's safety speed for the safety observation function.
Set a value to hold the following relationship.
SV239=(SV238/SV018) x (SV002/SV001)
Only when the product is 0, set to "1".
When not using, set to "0".
Related parameters: SV033/bitD, SV113/bitF, SV239
---Setting range---
0 to 32767 (r/min)
【#2440-2443】 SV240 - SV243
Not used. Set to "0".
【#2444(PR)】 SV244 DUNIT Communication interpolation unit for communication among
drive units
Set the communication interpolation unit among drive units.
When set to "0", it will be regarded as 20 (0.05μm) is set.
Related parameters: SV129
---Setting range---
0 to 2000 (1/μm)
【#2445-2456】 SV245 - SV256
Not used. Set to "0".
M700VS Series Setup Manual
Appendix 1.4 Servo Parameters
351