MITSUBISHI CNC
Appendix 1 Explanation of Parameters
【#2233】 SV033 SSF2 Servo function 2
Select the servo functions.
A function is assigned to each bit.
Set this in hexadecimal format.
bit F : lmc2a Lost motion compensation 2 timing
0: Normal
bit E : zup Vertical axis pull up function
0: Stop
Related parameters: SV032, SV095
bit D : rps Speed setting increment
Change the setting units of the specified speed signal output speed (SV073) and safety observation
safety speed (SV238).
0: mm/min
Related parameters: SV073, SV238
bit C-8 :
Not used. Set to "0".
bit 7-5 : nfd2 Depth of Notch filter 2
Set the depth of Notch filter 2 (SV046).
bit7,6,5=
000: - ∞
001: -18.1[dB]
010: -12.0[dB]
011: -8.5[dB]
100: -6.0[dB]
101: -4.1[dB]
110: -2.5[dB]
111: -1.2[dB]
Set the adaptive frequency of Notch filter 2 in "#2246 SV046 FHz2".
bit 4 : nfd3 Notch filter 3
0: Stop
bit 3-1 : nfd1 Depth of Notch filter 1
Set the depth of Notch filter 1 (SV038).
bit3,2,1=
000: - ∞
001: -18.1[dB]
010: -12.0[dB]
011: -8.5[dB]
100: -6.0[dB]
101: -4.1[dB]
110: -2.5[dB]
111: -1.2[dB]
Set the adaptive frequency of Notch filter 1 in "#2238 SV038 FHz1".
bit 0 : zck Feedback error alarm 42 detection
This ignores the false detection of alarms when using multipoint Z phase scale including distance-
coded reference scale.
0: Normal setting
330
1: Change
1: Enable
1: 100mm/min
1: Start (1,125Hz)
1: Disable
zck
nfd1
nfd3
nfd2
rps
zup
lmc2a