M01 Mixed sync ctrl disable modal 1035
Details
Mixed control (cross axis control) was commanded for a part system in which the mixed control (cross
axis control) is disabled as shown below.
- During nose R compensation mode
- During pole coordinate interpolation mode
- During cylindrical interpolation mode
- During balance cut mode
- During fixed cycle machining mode
- During facing turret mirror image
- During constant surface speed control mode
- During hobbing mode
- During axis name switch
An axis was transferred to another part system, and mixed control was attempted with the part
system's maximum number of control axes exceeded.
An axis was removed from the part system, and mixed control was attempted with the part system's
number of axes zero.
Another axis exchange was attempted to the axis which was already transferred to another part
system for mixed control.
Remedy
- Correct the program.
M01 Synchro ctrl setting disable 1036
Details
"Synchronous control operation method" was set (with R2589) when the mode was not the C axis
mode.
"Synchronous control operation method" was set (with R2589) in the zero point not set state.
Mirror image is disabled.
External mirror image or parameter mirror image was commanded during facing turret mirror image.
Remedy
- Set the contents of the R2589 register to "0".
- Correct the program and parameters.
M01 Synchro start/cancel disable 1037
Details
Synchronous control start/cancel command was issued when the start/cancel is disabled.
Remedy
- Correct the program and parameters.
M01 Move cmnd invld to synchro ax 1038
Details
A travel command was issued to a synchronous axis in synchronous control.
Remedy
- Correct the program.
M01 No spindle speed clamp 1043
Details
The constant surface speed command (G96) was issued to the spindle which is not selected for the
spindle speed clamp command (G92/G50) under Multiple spindle control II.
Remedy
Press the reset key and carry out the remedy below.
- Select the spindle before commanding G92/G50.
M01 Sp synchro phase calc illegal 1106
Details
Spindle synchronization phase alignment command was issued while the "phase shift calculation
request" signal was ON.
Remedy
- Correct the program.
- Correct the sequence program.
M700VS Series Setup Manual
Appendix 2.1 Operation Errors (M)
513