【#2295】 SV095 ZUPD Vertical axis pull up distance
Set this parameter to adjust the pull up distance when the vertical axis pull up function is enabled.
When the pull up function is enabled and this parameter is set to "0", for a rotary motor, 8/1000 of a
rotation at the motor end is internally set as the pull up distance, and for a linear motor, 80[μm] is
set.
Related parameters:
SV032 : The pull up direction is determined. When "0" is set, pull up control is not executed.
SV033/bitE : Start-up of the pull up function
SV048 : Set the drop prevention time. When "0" is set, pull up control is not executed.
---Setting range---
0 to 2000 (μm)
【#2296】 SV096
Not used. Set to "0".
【#2297】 SV097
Not used. Set to "0".
【#2298】 SV098
Not used. Set to "0".
【#2299】 SV099
Not used. Set to "0".
【#2300】 SV100
Not used. Set to "0".
【#2301】 SV101
Not used. Set to "0".
【#2302】 SV102
Not used. Set to "0".
【#2303】 SV103
Not used. Set to "0".
【#2304】 SV104
Not used. Set to "0".
【#2305】 SV105
Not used. Set to "0".
【#2306】 SV106
Not used. Set to "0".
【#2307】 SV107
Not used. Set to "0".
【#2308】 SV108
Not used. Set to "0".
【#2309】 SV109
Not used. Set to "0".