【#17200 - 17455】 C000 - C255 Counter
Set the time for the counter used with the PLC program (ladder).
(Note1) This setting value is valid when bit selection parameter "#6449/bit1" is set to "0".
(Note2) Setting the counter setting value from the setting and display unit
(Note3) As described bellow, the setting method of counter C and No. of points can be set with the
---Setting range---
0 to 32767
【#18001 - 18150】 R7500,7501 - R7798,7799 PLC constant (Base area)
Set the value to be set in the data type R register used in the PLC program (ladder).
Even if the data is set in the R register that corresponds to the PLC side when this parameter is
displayed. The screen will not change.Enter a different screen once, and then select this screen
again.
---Setting range---
-99999999 to 99999999
【#18151-18900】 R8300,8301 - R9798,9799 PLC constant (Extension area)
Set the value to be set in the data type R register(R8300 to R9799) used in the PLC program
(ladder).
Even if the data is set in the R register that corresponds to the PLC side when this parameter is
displayed, the screen will not change. Enter a different screen once, and then select this screen
again.
#18151 to #18900 is used as the PLC constant extended area.
The area is valid for the number of PLC constant extension points ("#1326 PLC Const Ext. Num"
setting value), starting with #18151.
---Setting range---
-99999999 to 99999999
The counter C setting value can be set with the following two methods.
- Method to validate the setting value (Kn) programmed with the sequence program (fixed
counter)
- Method to validate the setting value set from the setting and display unit (variable counter)
bit selection parameters (#6454/bit4 to bit7).
- #6454/bit4=0, bit5=0, bit6=0, bit7=0
No. of points: 0
Range: None
Setting method: All fixed counters
- #6454/bit4=1, bit5=0, bit6=0, bit7=0
No. of points: 40
Range: #17200 to #17239
Setting method: Set above range with variable counter.
- #6454/bit4=0, bit5=1, bit6=0, bit7=0
No. of points: 80
Range: #17200 to #17279
Setting method: Set above range with variable counter.
- #6454/bit4=1, bit5=1, bit6=0, bit7=0
No. of points: 120
Range: #17200 to #17319
Setting method: Set above range with variable counter.
- #6454/bit4=0, bit5=0, bit6=1, bit7=0
No. of points: 160
Range: #17200 to #17359
Setting method: Set above range with variable counter.
- #6454/bit4=1, bit5=0, bit6=1, bit7=0
No. of points: 200
Range: #17200 to #17399
Setting method: Set above range with variable counter.
- #6454/bit4=0, bit5=1, bit6=1, bit7=0
No. of points: 240
Range: #17200 to #17439
Setting method: Set above range with variable counter.
- #6454/bit4=1, bit5=1, bit6=1, bit7=0
No. of points: All points
Range: #17200 to #17455
Setting method: All variable counters
M700VS Series Setup Manual
Appendix 1.8 PLC Constants
419