Acceleration/deceleration [G]
Acceleration/deceleration are available on servo amplifiers with firmware version A5 or later.
Acceleration/deceleration is performed in accordance with the specified acceleration/deceleration [command unit/s
the acceleration/deceleration time constants, acceleration/deceleration can be performed independent of the rated speed of
the servo motor.
The control mode influences whether the acceleration/deceleration is set in the control mode.
Setting example
To accelerate at 0.5 [s] from 0 [command unit/s] to 1500 [command unit/s], set 3000 [command unit/s
To decelerate at 2 [s] from 1500 [command unit/s] to 0 [command unit/s], set 750 [command unit/s
Speed [command unit/s]
Servo motor speed
Acceleration time =
Acceleration/deceleration
[command unit/s
Acceleration
Deceleration
Precautions
• The servo parameter for setting the acceleration/deceleration data varies depending on the unit selected in [Pr. PT01.1
Speed/acceleration/deceleration unit selection]. However, the same object is used for setting the acceleration/deceleration
data regardless of the unit selected. Refer to [Pr. PT01.1] for details. For the precautions for each acceleration/deceleration
data, refer to the setting servo parameters, point table, and objects.
Servo motor speed
Acceleration
2
]
Servo motor speed
Deceleration time =
Deceleration
3.20 Acceleration/deceleration function [G] [A]
2
]. Unlike
2
] for the acceleration.
2
] for the deceleration.
Time [s]
Time [s]
3 BASIC FUNCTION
3
193