When connecting multiple MR-J5D_-G_ to one MR-CV, set [Pr. PC46.2 Protection coordination multiple
connections selection] to "1".
• When an alarm that is subject to the converter main circuit stop occurs
When an alarm is detected, MBR and CVST are turned off, and the servo motor is stopped using the dynamic brake and
electromagnetic brake.
When an alarm that is subject to the converter main circuit stop occurs in an MR-J5D_-_G_, the other MR-J5D_-_G_
connected with the protection coordination cable also stops the servo motor.
For the alarms that are subject to the converter main circuit stop, refer to "List of alarm No./warning No." in the following
manual.
MR-J5 User's Manual (Troubleshooting)
First MR-J5D_-_G_
0 r/min
Servo motor speed
First MR-J5D_-_G_
Base circuit
(Energy supply to the servo motor)
Display of the first MR-J5D_-_G_
First MR-J5D_-_G_
MBR
(Electromagnetic brake interlock)
First MR-J5D_-_G_
CVST
(Converter stop)
Second MR-J5D_-_G_
Servo motor speed
Second MR-J5D_-_G_
Base circuit
(Energy supply to the servo motor)
Display of the second MR-J5D_-_G_
Second MR-J5D_-_G_
MBR
(Electromagnetic brake interlock)
Second MR-J5D_-_G_
CVST
(Converter stop)
MR-CV display
Alarm occurrence in the first MR-J5D_-_G_
ON
OFF
No alarm
ON
OFF
ON
(No alarm)
OFF
(Alarm)
0 r/min
ON
OFF
No alarm
ON
OFF
ON
OFF
Braking with dynamic brake
Braking with dynamic brake and
electromagnetic brake
Alarm No.
Operation delay time of electromagnetic brake
CVST turns off upon detection of the alarm.
Delay time until a protection coordination error is detected
Braking with dynamic brake upon detection of the
protection coordination error
Braking with dynamic brake and
electromagnetic brake
The alarm that occurred in the first MR-J5D_-_G_
allows for the protection coordination error to
be detected.
[AL. 01B Protection coordination error]
Operation delay time of electromagnetic brake
CVST turns off upon detection of the alarm.
No alarm
3 BASIC FUNCTION
167