hit counter script

Configuring Mac Threshold Notification Traps - Cisco Catalyst 2960 Software Configuration Manual

Hide thumbs Also See for Catalyst 2960:
Table of Contents

Advertisement

Chapter 5
Administering the Switch

Configuring MAC Threshold Notification Traps

When you configure MAC threshold notification, an SNMP notification is generated and sent to the
network management system when a MAC address table threshold limit is reached or exceeded.
Beginning in privileged EXEC mode, follow these steps to configure the switch to send MAC address
table threshold notification traps to an NMS host:
Command
Step 1
configure terminal
Step 2
snmp-server host host-addr {traps | informs} {version {1
| 2c | 3}} community-string notification-type
Step 3
snmp-server enable traps mac-notification threshold
Step 4
mac address-table notification threshold
Step 5
mac address-table notification threshold [limit
percentage] | [interval time]
Step 6
end
Step 7
show mac address-table notification threshold
show running-config
Step 8
copy running-config startup-config
OL-26520-01
Purpose
Enter global configuration mode.
Specify the recipient of the trap message.
Enable the switch to send MAC threshold
notification traps to the NMS.
Enable the MAC address threshold notification
feature.
Enter the threshold value for the MAC address
threshold usage monitoring.
Return to privileged EXEC mode.
Verify your entries.
(Optional) Save your entries in the configuration file.
Catalyst 2960 and 2960-S Switches Software Configuration Guide, Release 15.0(1)SE
Managing the MAC Address Table
For host-addr, specify the name or address of the
NMS.
Specify traps (the default) to send SNMP traps
to the host. Specify informs to send SNMP
informs to the host.
Specify the SNMP version to support. Version 1,
the default, is not available with informs.
For community-string, specify the string to send
with the notification operation. Though you can
set this string by using the snmp-server host
command, we recommend that you define this
string by using the snmp-server community
command before using the snmp-server host
command.
For notification-type, use the mac-notification
keyword.
(Optional) For limit percentage, specify the
percentage of the MAC address table use; valid
values are from 1 to 100 percent. The default is
50 percent.
(Optional) For interval time, specify the time
between notifications; valid values are greater
than or equal to 120 seconds. The default is 120
seconds.
5-19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Catalyst 2960-s

Table of Contents