hit counter script

Configuring The Web-Based Authentication Parameters - Cisco Catalyst 2960 Software Configuration Manual

Hide thumbs Also See for Catalyst 2960:
Table of Contents

Advertisement

Chapter 11
Configuring Web-Based Authentication
Specifying a Redirection URL for Successful Login
You can specify a URL to which the user is redirected after authentication, effectively replacing the
internal Success HTML page.
Command
ip admission proxy http success redirect url-string
When configuring a redirection URL for successful login, consider these guidelines:
This example shows how to configure a redirection URL for successful login:
Switch(config)# ip admission proxy http success redirect www.cisco.com
This example shows how to verify the redirection URL for successful login:
Switch# show ip admission configuration
Authentication Proxy Banner not configured
Customizable Authentication Proxy webpage not configured
HTTP Authentication success redirect to URL: http://www.cisco.com
Authentication global cache time is 60 minutes
Authentication global absolute time is 0 minutes
Authentication global init state time is 2 minutes
Authentication Proxy Watch-list is disabled
Authentication Proxy Max HTTP process is 7
Authentication Proxy Auditing is disabled
Max Login attempts per user is 5

Configuring the Web-Based Authentication Parameters

You can configure the maximum number of failed login attempts before the client is placed in a watch
list for a waiting period.
Command
Step 1
ip admission max-login-attempts number
Step 2
end
Step 3
show ip admission configuration
Step 4
show ip admission cache
Step 5
copy running-config startup-config
This example shows how to set the maximum number of failed login attempts to 10:
Switch(config)# ip admission max-login-attempts 10
OL-26520-01
If the custom authentication proxy web pages feature is enabled, the redirection URL feature is
disabled and is not available in the CLI. You can perform redirection in the custom-login success
page.
If the redirection URL feature is enabled, a configured auth-proxy-banner is not used.
To remove the specification of a redirection URL, use the no form of the command.
Catalyst 2960 and 2960-S Switches Software Configuration Guide, Release 15.0(1)SE
Configuring Web-Based Authentication
Purpose
Specify a URL for redirection of the user in place of the
default login success page.
Purpose
Set the maximum number of failed login attempts. The
range is 1 to 2147483647 attempts. The default is 5.
Returns to privileged EXEC mode.
Display the authentication proxy configuration.
Display the list of authentication entries.
(Optional) Save your entries in the configuration file.
11-15