(2) 2-axis linear interpolation control (INC linear 2)
(a) Operation chart
In incremental system 2-axis linear interpolation control, designated 2 axes are used. Linear interpolation
positioning of movement amount set in "[Da.6] Positioning address/movement amount" is carried out from the
current stop position (start point address). The movement direction is determined by the sign of the movement
amount.
Y axis
movement
amount
Reverse
direction
When the axis 1 movement amount is 9000 and the axis 2 movement amount is -3000, positioning is
Ex.
carried out as follows.
Axis 2 movement
amount (-3000)
(b) Restrictions
An error will occur and the positioning will not start in the following cases. The machine will immediately stop if
the error is detected during positioning control.
• If the movement amount of each axis exceeds "1073741824 (=2
"[Pr.20] Interpolation speed designation method"
*1
The error "Outside linear movement amount range" (error code: 504) occurs at a positioning start. (The maximum
movement amount that can be set in "[Da.6] Positioning address/movement amount" is "1073741824 (=2
370
Forward direction (Y axis)
Start point address (X1,Y1)
(current stop position)
Y2
Y1
X1
X axis movement
amount
Reverse direction
Start point address
(current stop position)
Axis 2
4000
1000
0
1000
Axis 1 movement amount (9000)
Movement by linear interpolation
of the X axis and Y axis
Forward
direction (X axis)
X2
Stop address after the
positioning control
5000
10000
30
)" when "0: Composite speed" is set in
*1
Axis 1
30
)".)