(18)[Cd.20] Manual pulse generator 1 pulse input magnification
Item
This data item determines the factor by which the number of pulses from the manual pulse generator is magnified.
Setting details
• Value "0": read as "1".
• Value "1001" or less: read as "1000".
■Set with a decimal.
Setting
Setting value
value
Default value
1
Axis 1: 1522, 1523
Storage buffer memory
Axis 2: 1622, 1623
address
Axis 3: 1722, 1723
Axis 4: 1822, 1823
(19)[Cd.21] Manual pulse generator enable flag
Item
Setting details
This data item enables or disables operations using a manual pulse generator.
■Set with a decimal.
Setting value
Setting value
Default value
0
Axis 1: 1524
Storage buffer memory
Axis 2: 1624
address
Axis 3: 1724
Axis 4: 1824
(20)[Cd.22] New torque value
Item
• When changing the "[Md.35] Torque limit stored value", use this data item to specify a new torque limit stored value.
Setting details
• Set a value within the allowable range of the "[Pr.17] Torque limit setting value".
■Set with a decimal.
Setting
Setting value
value
Default value
0
Axis 1: 1525
Storage buffer memory
Axis 2: 1625
address
Axis 3: 1725
Axis 4: 1825
K
K
Manual pulse generator enable flag
0: Disable manual pulse generator operation.
1: Enable manual pulse generator operation.
K
CHAPTER 5 DATA USED FOR POSITIONING CONTROL
Description
Manual pulse generator
1 pulse input
magnification
1 to 1000
Description
Description
New torque value
1 to Pr.17 : Torque limit setting value
0
: Torque value is not changed
5