(3) Monitoring the current value
The "current feed value" and "machine feed value" are stored in the following buffer memory addresses, and can
be read using a "DFRO (P) instruction" or "DMOV (P) instruction" from the CPU module.
[Md.20] Current feed value
[Md.21] Machine feed value
(a) The following shows the examples of programs to read out the current feed value of
the axis 1 to D104 and D105 when X40 is turned ON.
• For the DFRO(P) instruction
• For the DMOV(P) instruction
354
Axis 1
Axis 2
800, 801
900, 901
802, 803
902, 903
Buffer memory address
Axis 3
1000, 1001
1002, 1003
\
Axis 4
1100, 1101
1102, 1103