12.7.8

Deceleration start flag function

The "deceleration start flag function" turns ON the flag when the constant speed status or acceleration status switches
to the deceleration status during position control whose operation pattern is "Positioning complete". This function can
be used as a signal to start the operation to be performed by other equipment at each end of position control or to
perform preparatory operation, etc. for the next position control.
For the "deceleration start flag function", the following will be explained.
• Control details
• Control precautions
• Setting method
• Checking of deceleration start flag
(1) Control details
When deceleration for a stop is started in the position control whose operation pattern is "Positioning complete",
"1" is stored into "[Md.48] Deceleration start flag". When the next operation start is made or the manual pulse
generator operation enable status is gained, "0" is stored.
(a) Start made with positioning data No. specified