(2) Setting positioning data
(a) Operating procedure
1.
Open the "Parameter" window.
Project window [Intelligent Function Module] Module name "Positioning_Axis_#_Data"
2.
Configure settings.
Double-click the setting-target item and select or enter a value.
• Items with a pull-down list
Double-click the item and select an item in the displayed pull-down list.
• Items without a pull-down list
Double-click the item and enter a value.
In the default status, the data displayed on "Positioning_Axis__Data" are only No. 1 to No. 100 of positioning data. To
display the data No. 101 and later, change the display range under "Display Specification of Positioning data".
[Tool] [Options...] "QD75/LD75 Type Positioning"
(Example) To display No.1 to No. 120 of positioning data
740