(c) Positioning data setting example
The following table shows the setting examples when " current value changing" is set in the positioning data
No. 1 of axis 1.
Setting item
[Da.1]
[Da.2]
[Da.3]
[Da.4]
Axis 1
[Da.5]
positioning
data No. 1
[Da.6]
[Da.7]
[Da.8]
[Da.9]
[Da.10]
Refer to Page 152, Section 5.3 for information on the setting details.
(2) Changing to a new current value using the start No. (No. 9003) for a current
value changing
(a) Operation chart
The current value is changed by setting the new current value in the current value changing buffer memory
"[Cd.9] Current value changing", setting "9003" in the "[Cd.3] Positioning start No.", and turning ON the
positioning start signal.
Positioning start signal
Md.20 Current feed value
(b) Restrictions
• The axis error "Outside new current value range" (error code: 514) will occur if the designated value is
outside the setting range when "degree" is set in "Unit setting".
• The error "Software stroke limit +" or "Software stroke limit -" (error code: 507 or 508) will occur if the
designated value is outside the software stroke limit range.
• The current value cannot be changed during stop commands and while the M code ON signal is ON.
• The M code output function is made invalid.
448
Setting example
Operation pattern
Control system
Acceleration time No.
Deceleration time No.
Axis to be interpolated
Positioning
address/movement amount
Arc address
Command speed
Dwell time
M code
OFF
[Y10,Y11,Y12,Y13]
50000
Set "Positioning complete" assuming that the next positioning data will
Positioning
not be executed. ("Continuous path control" cannot be set by current
complete
value change.)
Current value
Set the current value changing.
changing
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Set the address to which address change is desired. (Assuming "mm"
10000.0m
is set in "[Pr.1] Unit setting".)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Setting not required. (Setting value will be ignored.)
Set this when other sub operation commands are issued in combination
10
with the No. 1 positioning data.
ON
0
Current value changes to the
positioning address designated by
the current value changing buffer memory.
The above chart shows an example
when the positioning address is "0".
Setting details