hit counter script

Mitsubishi Electric MELSEC-L LD75P User Manual page 172

Positioning module
Hide thumbs Also See for MELSEC-L LD75P:
Table of Contents

Advertisement

Item
[Da.27] M code
ON signal
output timing
[Da.28] ABS
Positioning
direction in
option
degrees
[Da.29]
Interpolation
speed
designation
method
(12)Positioning option configuration
The positioning option consists of "[Da.27] M code ON signal output timing" to "[Da.29] Interpolation speed
designation method". The set values of those data are stored in one buffer memory address. Consider the
positioning option configuration in the figure below when setting "[Da.27] M code ON signal output timing" to
"[Da.29] Interpolation speed designation method".
Positioning option configuration
b15 b14 b13 b12 b11 b10 b9
(4)
(13)[Da.27] M code ON signal output timing
Set the M code ON signal output timing for each positioning data.
(14)[Da.28] ABS direction in degrees
Set the ABS moving direction when "degree" is selected as the unit for each positioning data.
(15)[Da.29] Interpolation speed designation method
Set the interpolation speed designation method for each positioning data.
● To use the positioning option, set "1: Valid" in [Pr.70] Positioning option valid/invalid setting.
● The positioning option can be set only with GX Works2 (Version 1.540N or later) or programs.
● The positioning option can be set only for the LD75 with a serial number (first five digits) of "17102" or later. If a value is
set for the positioning option of the LD75 with a serial number (first five digits) earlier than "17102" and a positioning
control is started, the value set in the positioning option is ignored.
170
Setting value, setting range
Value set with GX Works2
0: Use the set value in
"[Pr.18] M code ON signal
output timing".
1: WITH mode
2: AFTER mode
0: Use the set value in
"[Cd.40] ABS direction in
degrees".
1: ABS clockwise
2: ABS counterclockwise
3: Shortcut (direction setting
ignored)
0: Use the set value in
"[Pr.20] Interpolation speed
designation method".
1: Composite speed
2: Reference axis speed
b8
b7
b6
b5
b4
b3
b2
(3)
(2)
Default
Value set with program
0
1
2
0
1
2
3
0
1
2
(1) [Da.27] M code ON signal output timing
b1
b0
(2) [Da.28] ABS direction in degrees
(3) [Da.29] Interpolation speed designation method
(4) Use prohibited (fixed to 0)
(1)
Setting value buffer memory
address
value
Axis 1
Axis 2
0
0
2003
8003
0
Assignment
Axis 3
Axis 4
14003
20003

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec-l ld75d